You are currently viewing our boards as a guest which gives you limited access to view most discussions and access our other features. By joining our free community you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

If you have any problems with the registration process or your account login, please contact us.

Post New Thread Reply

Register GFY Rules Calendar
Go Back   GoFuckYourself.com - Adult Webmaster Forum > >
Discuss what's fucking going on, and which programs are best and worst. One-time "program" announcements from "established" webmasters are allowed.

 
Thread Tools
Old 02-19-2009, 09:50 PM   #1
tony286
lurker
 
tony286's Avatar
 
Industry Role:
Join Date: Aug 2002
Location: atlanta
Posts: 57,021
Video shooters I got a question

I upped the wattage of my light shooting to about 1750 watts of light. I like the look but Im worried about shooting in hotel rooms I dont want to trip the breaker. Do you know if hotel rooms are 20amps or 15? I had read that bathrooms in a hotel are on their own breaker do you know if this is true? Thanks
tony286 is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 09:58 PM   #2
NaughtyRob
Two fresh affiliate progs
 
NaughtyRob's Avatar
 
Industry Role:
Join Date: Nov 2004
Location: Inside teen pussy
Posts: 29,602
Very good question, I don't shoot in hotels but I would think the bathroom would be the best bet because they know people plug in hair dryers etc.
NaughtyRob is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:01 PM   #3
RevTKS69
Confirmed User
 
RevTKS69's Avatar
 
Join Date: Dec 2008
Location: West Texas
Posts: 231
Gfi

Almost all modern bathrooms have a GFI (Ground Fault Interupter) that's designed to keep people from dying if they drop the hair dryer in the sink or the bathtub. It's essentially a breaker right at the socket, but it may or may not be on it's own circuit.

Sorry, don't know the amperage information though.
__________________
www.sexyschiava.com - Amateur BDSM
www.adultblogreview.com - Starting a new review site, positions available
RevTKS69 is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:11 PM   #4
DirtyDanza
Confirmed User
 
DirtyDanza's Avatar
 
Industry Role:
Join Date: Aug 2002
Location: BP4L.... Las Vegas,
Posts: 8,369
your not going to trip anything.... you should see the setup I use at hotels here in vegas...

I run over 6000 wats of lighting.....

watts and amps are tottally different you can take a hit from 6000 watts and nothing will happen but it only takes 1 amp across your heart to kill you...

ohms law baby...

before porn I was a sparky
__________________
AVN Nominated Camming Couple
DirtyDanza is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:13 PM   #5
Barefootsies
Choice is an Illusion
 
Barefootsies's Avatar
 
Industry Role:
Join Date: Feb 2005
Location: Land of Obama
Posts: 42,635
Quote:
Originally Posted by GetNaughty View Post
Very good question, I don't shoot in hotels but I would think the bathroom would be the best bet because they know people plug in hair dryers etc.
__________________
Should You Email Your Members?

Link1 | Link2 | Link3

Enough Said.

"Would you rather live like a king for a year or like a prince forever?"
Barefootsies is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:17 PM   #6
DirtyDanza
Confirmed User
 
DirtyDanza's Avatar
 
Industry Role:
Join Date: Aug 2002
Location: BP4L.... Las Vegas,
Posts: 8,369
gfci are only in bathrooms to stop electrocutions and fires... they still carry the same rating and normal recipticles only rather than the breaker tripping the gfci will trip....

the thing to do is get power strips then you trip the power strip in the unlikley event... but I am willing to bet you will not trip anything...

to pull that many amps you need resistance something like heaters.. microwaves... lighting is lighting not that much resistance... how many amps does your lights pull maybe 7 amps tops? also remember that hotels are all 3phase which means in your room you will have a b c leg of power.... so plug in one plug that phase a another plug phase b and so forth... I mean really I load the fuck outta shit you should see my office LOL... at hotels I run 5 kinoflo 4 bay lights.. 2 diva's plus novatron strobes and computers all off 2 power strips ive only triped once... and it was my fault.. I was showing a trick to someone where you take live wire put it in bowl of water then stick your hand in there.. I triped the strip not the breaker and if you trip the breaker call hotel they will reset it...
__________________
AVN Nominated Camming Couple
DirtyDanza is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:19 PM   #7
Jim_Gunn
Confirmed User
 
Industry Role:
Join Date: Feb 2003
Location: Where The Teens Are
Posts: 5,702
The bigger problems with shooting in hotel rooms isn't the power, but the fact that you have some ugly, smallish hotel room as your set. You'll probably be okay with the power in any modern hotel, especially if you disperse the plugs around the room(s). I'd recommend bringing your own quilt with some nice bright color, some flowers or something else to add some color in the background and perhaps pull the bed away from the wall and find a way to throw a backlight on the bed, so the lighting doesn't look completely flat.
Jim_Gunn is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:21 PM   #8
tony286
lurker
 
tony286's Avatar
 
Industry Role:
Join Date: Aug 2002
Location: atlanta
Posts: 57,021
Thanks Danza
tony286 is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:21 PM   #9
DirtyDanza
Confirmed User
 
DirtyDanza's Avatar
 
Industry Role:
Join Date: Aug 2002
Location: BP4L.... Las Vegas,
Posts: 8,369
Quote:
Originally Posted by GetNaughty View Post
Very good question, I don't shoot in hotels but I would think the bathroom would be the best bet because they know people plug in hair dryers etc.
its all the same... im willing to bet the gfci is connected to at least 2 plugs in the room itself... I know when we built the belagio thats how we did it.... only reason gfci is in bathroom is it's code... same with kitchen and garage.... ever have a light go out in your house then find the gfci in the garage tripped? happends here in the rain it's just a saftey feature your I always overload shit with electrical

for some reason electric does not bother me.. ill work 480 live all day long on ac units at the disconnect.. but I am scared to death of propane and gas.. I won't even light the pilot on my fireplace LOLOL

but electrical is not that scary to me for some reason....

reminds me we were doing a repair job on top of the mirage here... I was working with an apprentace I told him always put one hand in your pocket when working live he did not listen and crossed phases with the ratchet and within 2 secs he chattered all his teeth out I had to double kick him off....
__________________
AVN Nominated Camming Couple
DirtyDanza is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:22 PM   #10
tony286
lurker
 
tony286's Avatar
 
Industry Role:
Join Date: Aug 2002
Location: atlanta
Posts: 57,021
Quote:
Originally Posted by Jim_Gunn View Post
The bigger problems with shooting in hotel rooms isn't the power, but the fact that you have some ugly, smallish hotel room as your set. You'll probably be okay with the power in any modern hotel, especially if you disperse the plugs around the room(s). I'd recommend bringing your own quilt with some nice bright color, some flowers or something else to add some color in the background and perhaps pull the bed away from the wall and find a way to throw a backlight on the bed, so the lighting doesn't look completely flat.
good ideas thank you. Jazz the room up a bit.
tony286 is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Old 02-19-2009, 10:28 PM   #11
tony286
lurker
 
tony286's Avatar
 
Industry Role:
Join Date: Aug 2002
Location: atlanta
Posts: 57,021
The reason I asked is because I had read this "Also realize that 2000w is about all you are going to get from any single household 120v outlet; household breakers are usually either 15 or 20 amps (remember the "West Virginia Law" W = VA. So with a 120volt system you would have 15 x 120 = 1800watts on a 15 amp breaker or 20 x 120 = 2400 watts on a 20 amp breaker. It's a bad idea to push this to the limit also."

So thats why I asked.
tony286 is offline   Share thread on Digg Share thread on Twitter Share thread on Reddit Share thread on Facebook Reply With Quote
Post New Thread Reply
Go Back   GoFuckYourself.com - Adult Webmaster Forum > >

Bookmarks



Advertising inquiries - marketing at gfy dot com

Contact Admin - Advertise - GFY Rules - Top

©2000-, AI Media Network Inc



Powered by vBulletin
Copyright © 2000- Jelsoft Enterprises Limited.